Installation of NonStop Server based files (manual method)

 

If the MOMIFTP utility cannot be used to transfer files from the PC to the NonStop server, these instructions describe how an alternate file transfer program would be used. The MOMIFTP utility does not perform any special actions, but simply renames files (if existing are present) and transfers MOMI files from the PC to the NonStop System using FTP or SFTP.

 

The first step is to locate the source files -

 

 

PC install all users:

 

C:\Program Files (x86)\BlackWood Systems\BWS MOMI n.nn\Tandem Install\NonStop\

 

PC install user only:

 

C:\Users\<User ID>\AppData\Local\Programs\BlackWood Systems\BWS MOMI n.nn\Tandem Install\NonStop\

 

Via shared server (varies based on how shared server is organized):

 

\Tandem Install\NonStop\

 

(where n.nn is the release package number)

 

If MOMI is not installed, download and execute the MSI file. Select Launch CentralServer and place the files in an empty subdirectory. In the destination subdirectory under \Tandem Install\NonStop are the subdirectories \ascii and \Binary. The grouping indicates the needed file transfer mode (i.e. ASCII or Binary).

 

The second step, using a file transfer utility, copy files from the PC to the NonStop (all to the same destination subvolume) -

 

Binary

BWMOMI

BWMOMIi

BWMOMIx

EMSEXPO

 

ASCII

FUPEVTCX

OBYMOMI

CONFMOMI

OBYCSQL

OBYALTER

 

The third step is to logon to the NonStop System, volume to the location where the files were placed and OBEY the TACL obey file OBYALTER to alter the file codes (or manually perform the steps below):

a) FUP alter BWMOMI  ,code 700

b) FUP alter BWMOMIi ,code 800

c) FUP alter BWMOMIx ,code 500

d) FUP alter EMSEXPO ,code 845

 

At this point the files are transferred. Continue the instructions in the section First Installation Update an existing installation after the step using MOMIFTP.